干bb视频_欧美无毛逼_在线天堂网新版_亚洲精品中_男人天堂资源网_欧美性XXXXX极品娇小_艳妇乳肉豪妇荡乳A片色戒_黄网入口_亚洲va欧美va国产va天堂影院_成年妇女观看在线视频_我想看免费的毛片_懂色av一区二区三区在线播放_555夜色666亚洲国产免_国产v片在线观看_国产乱了实正在真_国产成人综合av_夜夜看_东北少妇不带套对白_狠狠躁夜夜_中文字幕 日韩高清_666夜色成人免费视频观看_日本xxx性_欧美日韩免费大片_3344www成人_91av伊人_www.91操_国产一三四2021不卡_久草高清视频_亚洲 欧美 制服 综合 另类_亚洲精品亚洲人成在线观看麻豆

?

常州市衡正電子儀器有限公司是一家集軟件開發(fā)、制造、銷售、服務(wù)于一體的科技型現(xiàn)代化企業(yè)。
掃描手機(jī)二維碼
掃描微信二維碼
13861223798

新聞中心

NEWS CENTER

網(wǎng)站公告:測試信息來自互聯(lián)網(wǎng),若涉及侵權(quán),請聯(lián)系我們刪除! 您當(dāng)前所在位置:首頁 > News > Industry information > 正文返回

Viscometer in the use of the process to be aware of several issues

更新時(shí)間:2017-04-20 10:36:54點(diǎn)擊次數(shù):4276次字號:T|T
Rotational viscometer is widely used in the determination of oil, paint, paint, plastics, food, drugs, adhesives and other dynamic viscosity of the fluid. The instrument is simple, cheap, convenient and practical, and thus popular. In the long process of
Rotational viscometer is widely used in the determination of oil, paint, paint, plastics, food, drugs, adhesives and other dynamic viscosity of the fluid. The instrument is simple, cheap, convenient and practical, and thus popular. In the long process of testing the instrument, we found that many users, especially small and medium-sized enterprise test personnel in the course of the existence of many problems, often we test the performance of the instrument is better than the requirements of national measurement procedures, but the user in the test sample When the data deviation is very large. Now on how to correctly use this type of instrument to obtain accurate and reliable measurement results are as follows.

First of all, a brief introduction to the measurement of the instrument principle:
After the start of the rotary viscometer, it is necessary to first detect the zero position. This operation is normally carried out without the installation of the rotor. Then, the inner cylinder of the radius R2 is coaxially mounted in the outer cylinder of the radius R1, which is filled with viscous fluid, To rotate at a steady speed, successive discs, and then through the hairspring and shaft to drive the inner cylinder that is the rotor rotation, the inner tube that is the role of fluid-based viscous moments, the greater the role of the gossamer to compete with the resulting The greater the torque, so the pointer on the dial indicates the greater the scale. Multiplying the reading by a specific coefficient yields the dynamic viscosity of the liquid.

According to its measurement principle, in order to obtain accurate and reliable measurement data must pay attention to the following points:
First, the performance of the instrument must meet the requirements of the national measurement procedures. In the use of the instrument to carry out periodic testing, if necessary (the instrument used frequently or in a critical state) to conduct an intermediate self-examination to determine its metrological performance, coefficient error within the allowable range, or can not get accurate data.

Second, pay special attention to the measured liquid temperature. Many users ignore this point, that the temperature difference does not matter, our experiments show that: when the temperature deviation of 0.5 ℃, some liquid viscosity value deviation of more than 5%, the temperature deviation of a great impact on viscosity, temperature, viscosity decreased. So pay special attention to the measured liquid temperature is constant in the vicinity of the specified temperature, the best measurement is best not to exceed 0.1 ℃.

Third, the measurement of the container tube selection. For the double cylinder rotary viscometer to carefully read the instrument manual, different rotor cylinder matching the corresponding tube, otherwise the measurement results will be a huge deviation. For a single cylinder rotary viscometer, the principle of the outer radius of the outer tube is infinitely large, the actual measurement requirements of the outer cylinder that is measured the inner diameter of the container is not less than a certain size. For example, the Shanghai Tianping Instrument Factory produced NDJ-1 type rotary viscometer, requires the measurement of beakers or straight barrel with a diameter of not less than 70mm. Experiments show that, especially in the use of a rotor, if the container diameter is too small to cause a larger measurement error.

Fourth, the correct choice of the rotor or adjust the speed, so that the value between 20 to 90 cells.
The instrument uses a dial plus pointer readings, its stability and readings are combined together with 0.5 cells, if the reading is too small as 5 cells near the relative error caused by more than 10%, if you choose the right rotor or speed to make Reading in 50 cells, then the relative error can be reduced to 1%. If the indication is more than 90 cells, so that the hairspring produced by the torque is too large, easy to produce creep, damage hairspring, so be sure to correctly select the rotor and speed.

5, frequency correction. For the nominal frequency of domestic equipment at 50Hz, and China's current power supply frequency is 50Hz, we use the frequency meter to test the variability of less than 0.5%, so the general measurement does not require frequency correction. But for Japan and Europe and some of some instruments, the nominal frequency of 60Hz, must be frequency correction, otherwise it will produce 20% of the error, the correction formula is:
Actual viscosity = indicated viscosity × nominal frequency ÷ actual frequency

Six, the rotor immersed in the depth of the liquid and the impact of bubbles.
Rotational viscometer on the rotor immersed in the depth of the liquid has strict requirements, must be in accordance with the instructions required to operate some of the two-cylinder instrument on the test of the amount of liquid has strict requirements, must be measured with a cylinder. The rotor is immersed in the process of the liquid often with bubbles in the rotor after a period of time most of the floating will disappear, attached to the lower part of the rotor bubbles can not be eliminated, the existence of bubbles will give the measurement data to bring a large deviation, so tilt Slowly immersing the rotor is an effective way.

Seven, the rotor cleaning. The measuring rotor includes the outer cylinder to be clean and free of dirt. It is usually cleaned in time after the measurement, especially after measuring the paint and the adhesive. Pay attention to the cleaning method, you can use the appropriate organic solvent soak, do not use metal tools such as hard scraping, because the rotor surface with a serious scratch will bring the measurement results of the deviation.
(編輯:HengZheng)
0 條評論
不想登錄?直接點(diǎn)擊發(fā)布即可作為游客留言。

新聞中心列表

公司新聞
行業(yè)資訊

新聞推薦

電子天平使用應(yīng)具備的基本知識

電子密度天平計(jì)量檢定項(xiàng)目

在日常的周期檢定和常規(guī)的產(chǎn)品質(zhì)量檢查中,一般需要檢定以下幾項(xiàng)內(nèi)容...

JA系列電子天平選購應(yīng)該注意哪...

JA系列電子天平對操作人員的兼容性和對操作環(huán)境的耐受能力。

如何正確使用FA系列電子天平?

準(zhǔn)備將FA系列電子天平放在穩(wěn)定的工作臺上,避免振動,氣流、陽光直...

FA系列電子天平使用的注意事項(xiàng)

電子天平如何測量固體密度

鹵素水分測定儀操作過程

聯(lián)系我們

地址:江蘇省常州市鐘樓區(qū)龍城大道2188號新閘科技園

聯(lián)系人:查小姐
郵編:213000
電話:0519-83263587
傳真:0519-83268313
網(wǎng)址:http://www.cqyuzhan.com/

聯(lián)系我們
地址:常州市鐘樓區(qū)龍城大道2188號新閘科技園10棟313
聯(lián)系人:查小姐
電話:0519-83263587
傳真:0519-83268313
網(wǎng)址:http://www.czhz17.com
關(guān)注衡正
Copyright ? 2017 - 2024 All Rights Reserved 常州市衡正電子儀器有限公司 版權(quán)所有  蘇ICP備17024635號 技術(shù)支持:冉冉科技 網(wǎng)站地圖 
文登市| 滨州市| 涞水县| 涪陵区| 嫩江县| 平利县| 永德县| 陕西省| 方城县| 延安市| 顺昌县| 习水县| 西城区| 宁都县| 延长县| 德庆县| 衡南县| 麻栗坡县| 蒲江县| 方山县| 上栗县| 方城县| 浦城县| 正蓝旗| 金山区| 锡林浩特市| 东乌| 沙河市| 澄迈县| 万荣县| 九寨沟县| 灵丘县| 年辖:市辖区| 本溪市| 宁安市| 吉林省| 左贡县| 大邑县| 泰安市| 廉江市| 和田县|